General Description
The Balloon Inflation and Launch Shelter (BILS) is a low cost system
providing a shelter for preparation and launching of radiosondes and sounding
balloons for upper air observations. It is compatible with most commercial
radiosondes. The BILS is ideal for either ground or roof mounting.
Features
- Shelters radiosonde balloon and
operator from the weather prior to release
- Remote or local roof or release
control
- Provides consumable storage space
- Sounding balloons up to 800g
Applications
- Operational Weather: Upper air
observing balloon management system for government and military applications
- Semi-automated synoptic
observations
- Numerical Weather Prediction:
Input for weather forecast models
- Scientific research field
experiments on global climate change and severe weather
Installation and Hardware Features
Best design practices are used throughout the BILS so it will provide years
of trouble free operation. Ground mounted BILS systems are typically set on
concrete slabs and secured to J-bolts. It can also be mounted on rooftops having
suitable concrete or steel structures. The BILS enclosure is made from seam
welded aluminum plate, with an RF-transparent upper Plexiglass
portion to permit GPS radiosondes to lock onto satellites prior to release. If
the air foil option is installed, the overall width increases to 12′W). When
the BILS door hatch is open, the overall length is 20′. However, with the door
closed the building dimensions are 14′L x 8′W x 11′H (height to top of
door), plus two feet on either end for the steel frame. Four eye hooks are
provided on skid corners to permit crane lifting.
BILS-9004 Balloon Inflation and Launch Shelter (shown without optional air
foils).
A steel base plate frame extends beyond the 14′L aluminum BILS inflation
chamber, providing ample space for user-supplied helium gas tanks. In addition
to providing tank storage, it adds mechanical rigidity to the system and permits
flexible roof attachment. A fork lift can move the unit if necessary. At sites
where the tank farm must be remote located for logistics, gas can be piped in.
An adjustable helium gas regulator and solenoids control gas flow and a
user-provided meter can log gas use.
The balloon inflation chamber is 8′ in diameter and 11′ high, and
supports launching up to 800 gm balloons. The inside of this area is covered
with a soft polyethylene sheathing curtain that protects the balloon from
contact with sharp objects inside the inflation chamber. During inflation, a
rubber gas line holds the balloon centered to eliminate contact between the
balloon and the inflation chamber sheathing or the hatch roof.
An adjacent 8′W x 7′H x 5W L storage compartment with 36″ workbench
provides an area for operators to keep out of inclement weather during balloon
and radiosonde supply. A locker is provided for expendable and small tool
storage. A door separates the inflation area from the storage compartment, and
non-skid floors have drainage holes.
System Control
Inside the storage compartment is a combination system control and inflation
panel, with an embedded processor. The system controller monitors various
parameters such as air temperature and switches. It activates the roof hatch
motor, cutter servos and gas solenoids for balloon and roof control.
Operators can prepare the radiosonde and sounding balloon train in the BILS
storage compartment and then inflate, open the roof hatch and release the
balloon either from within the storage compartment (locally) or remotely
controlled via the RS-232 system interface. Each BILS system includes ALEX, a
MS-Windows application that monitors system activity. It can be installed on a
local or remote user-supplied PC that is connected to the system via RS-232. For
example, this application can be run on a nearby forecast office PC providing
critical balloon release timing window information.
The control system monitors status, outdoor sensors and inflation compartment
temperature. It provides these outputs:
- Inflation compartment blower
status
- Helium gas estimate
- Automatic gas shut off valve
operation
- Door hatch position and status
- Door hatch latch status
- Balloon hold down and release
status
The CPU monitors the status of the following switches: ventilation blower,
roof open limit and open over travel, roof closed and closed over limit, balloon
launch, gas and hatch locked. All wiring meets national electrical code
requirements. If the Heater option is provided for use in colder climates, an
exterior weatherproof circuit breaker/junction box is provided for 208/240 Vac
connection to customer AC mains. Otherwise the system plugs into a standard 110V
outlet.
Safety and Interlocks
The roof hatch is locked in the open position by a safety locking solenoid.
Door hatch travel and position detection is made via a precision analog position
sensor and motor speed is slowed nearing the end travel. If the system detects
over travel it requires a manual reset.
Hatch Motion
The BILS roof hatch control system is based on YES′ proven ARL radiosonde
management technology. Several different streaming video demonstrations of hatch
motion in action are provided in Media Player and Real Video at:
http://www.yesinc.com/products/demos/wx.html
Restraint Release Mechanism
Balloon neck release is controlled by a servo linked to the system embedded
controller via a fiber optic link. An emergency manual local manual safety
override is provided. In addition to RS-232 remote control, local balloon
release and roof pushbutton controls are mounted on the control panel inside the
storage compartment. The RS-232 interface provides system status in near real
time including current roof position, inside and outside temperature, and
critical fault conditions such as roof actuator failure.
The roof hatch is curved to shed snow and is controlled by a widely available
COTS weatherproof electromechanical ball screw capable of more than a 2000 lb.
load. This reliable internal ball screw roof motor drive provides an added level
of safety as the system controller monitors motor current to detect a jam
conditions and halts roof motion. Although the roof cannot be moved without
removing the ball screw drive, a separate solenoid latches the roof in the open
position to permit safe maintenance.
Ventilation and Lighting
Four internal blower fans aspirates outdoor air through nonconductive
ducting. Inflation chamber and outdoor air temperature is monitored. An outside
70 watt high pressure sodium lamp provides general area illumination near the
door area and is under photocell control. Inside the storage compartment and the
inflation chamber are sealed, low temperature rated, weatherproof florescent
lamps for area lighting.
For convenience, 110Vac 15A electrical outlets are provided in the inflation
chamber, storage compartment and outside.
Available Options
- 24″ air foils on three sides
of the chamber support operation at high wind sites
- Heater and A/C option (208/240
Vac, 60 Hz 30A)
- METHUB Meteorological Data
Receiver for YES radiosondes
- Automatic balloon helium gas
meter
- PTU-2000 or MET-2010 aspirated
thermohygrometer and pressure sensor (provides P/T/U ground truth)
- TSI-880 Total Sky Imager
(provides remote monitoring of release)
Development History
The BILS was initially developed by the National Center for Atmospheric
Research and several systems were delivered to NWS research offices in the mid
1990s. Its goal is to semi-automate labor intensive human-operated soundings. In
1998, YES received a Phase II SBIR award from the United States Department of
Energy to develop a fully-automated radiosonde launcher for 600 gm balloons
(Models ARL-9000/MERV-9200.) In 2003, YES received a SBIR award from NOAA to
develop a semi automated, single radiosonde launch system. YES engineers worked
to adapt the original NCAR BILS to address weatherability and provide
compatibility with NWS′ evolving Radiosonde Replacement System and new GPS
radiosonde technology.
Specifications |
Operating Temperature
-40° C to +44°
C |
Weight/Size
Approx. 4200 lbs. unloaded (no options);5200 lbs. (with options)
14′ long x 8.5′ wide x 11′ high (closed) 20′ long (open);
Width increases to 11.5′ when heater A/C option is installed;
Width increases to 12.5′ when air foil option is installed. |
Power Requirements
110/208 Vac 50/60 Hz 280 watts (4000W w/Heater/AC option)
110/208 Vac 60 A single phase exterior rated service panel
All-metal construction provides lighting protection via chassis. |
Launch Wind Speed Limits
≤ 45 mph operational, 120 MPH storage with
suitable tiedowns 30 lbs./sq. ft static roof snow load. 40 lbs./sq. ft
floor loads. |
BILS shown with the roof closed (left) and roof open (right). Airfoil and HVAC
options not shown.
Mechanical Interface Drawing (roof closed above and open below), dims in
inches [cm]
|